Energy Saver
Technical Systems (TSI) Series 42 Air cooled chiller with waterside economizer units have been specifically designed for applications requiring year-round operation to provide energy saving by reducing run time of compressorized equipment and taking advantage of the cool ambient temperature. Series 42 chillers are completely factory assembled including, air cooled fluid cooler, pump system, controller and all interconnecting wiring piping. We offer factory run (functional) test for all chillers prior to shipment as a standard option every day.
Whether you need great payback for the unit, green refrigerant unit or great lead time, our combined capability of specific application engineering and expertise in manufacturing custom equipment will provide limitless solutions for your needs.
Standard Featuress
Copeland compressor
Crankcase heater
- Compressor internal protection
- Compressor service valves
- Vibration isolation under scroll compressor
- Industrial duty 1140 rpm ODP motors with inherent electrical protection
- Internal fan motor protection
- Steel or aluminum blades depending on the model size
Condenser coil
Separate sub-cooling coil
- Condenser coils in galvanized steel frames
- Baffled condenser plenum
- Air cooled fluid cooler
Hydronic pumping system
Direct expansion shell and tube
Cabinets
- Liquid line drier and sight glass
- Liquid line solenoid
- Thermostatic expansion valve
- NEMA 3R/UL 508 label weather proof electrical panel
- Fan fusing
- Compressor fusing
- Fan motor contactors
- Compressor time delay (with more than one compressor units)
- High pressure safety
- Low pressure operating control
- Oil failure switch on each compressor for reciprocating compressor
- Freeze/low charge control with time delay circuit
- Return water temperature control
Water side economizer control system
- Fused control circuit
Fan cycling control down to +20˚F
- Easy access and service via removable panels
Pump down /run switch
- Easy access and service via removable panels
- Multiple rigging points
- ETL certified unit
- Fully assembled unit
- Initial refrigerant charge
- Functional test at the factory before shipment
List of Available Options
Protective grills
Totally enclosed fan motor
Fan circuit breaker
Compressor isolation
Coated coils
Disconnect switch
Receivers
Liquid line trim
Three-valve bypass
Refrigeration specialties
Gauges
Hot gas bypass
Cylinder unloading
Fan cycling
Flood control B-20
Control circuit transformer
Alarm circuit with horn
Unit circuit breaker
High altitude fan assembly
Off/Pump down/Run switch
Electrical door interlock
Convenience outlet
Phase failure / Under voltage protection
Low ambient lockout
Guaranteed off timer
Part winding start
Automatic lead lag
Elapsed time meters
Load limiting pressure stat
Microprocessor controls
Paint
Acoustic options
Hydronic accessories
Capacity Ranges
5 ton to 71 ton capacity depending on the conditions of service.
Unique Capabilities
- Left hand and right hand control panel locations
- Custom paint colors
- Circuit breakers in lieu of fuses
- Stainless steel cabinet construction
- VFD condenser fan application
- PLC controls
- Centrifugal fan – indoor application, sound critical application
- Sound attenuation package (850 rpm motor, centrifugal fan, sound blanket for compressor)
- Integral pump packages
- Integral storage tanks
- Integral glycol feed station
- Special applications – medical research, data processing, hazardous duty, plastic production, pharmaceutical, chemical processing and pulp & paper industries
|